2) AD086TI
Governor system for fuel injection pump consists of “Integral Actuator” and “Speed Control Unit”.
(1) Integral Actuator
•
Functions of Actuator’s component
1. Emergency stop lever
It is emergency stop lever operated by manual at emergency.
2. Upper control chamber
The cover for controlling the inside is installed.
3. Electro control chamber
Operating lever is started by the electric signal generated in it.
4. Adjusting screw
As it is a part of controlling the max. fuel amount if the length which comes outside is long
the torque decreases or if the length is short the torque increases.
5. Fuel stop plate
It is the plate which prevents fuel from increasing by stopping the proceeding of adjusting
screw.
6. Operating lever
It is a connecting lever for operating the fuel rack.
7. Fuel lever
It is connected with link lever, controls fuel amount of the fuel injection pump.
Caution :
Adjusting the fuel pump is an essential part for performance and endurance of engine,
therefore operation and maintenance should be performed only by specialized engineer.
- 123 -
<Side View> <Top View>
Emergency
mechanjcal stop
Injection
pump
Fuel rack
Fuel
stopplate
Stop nut
Fixation screw
Max. fuel
stop screw
Operating lever
Extreme stop position
of fuel rack
Linkage length L
Adjust linkage length so that
when fastened to the operating
lever the fuel rack is approx.
0.5-1.0mm away from its extreme
stop position
Operating lever
Upper chamber
Engine oil lubricated
The G.A.C actuator concept
Fastest responsotime
Maintenance free
Linear
Electromechanical chamber
Completety enclosed, and
seated