4-2. Control of ice maker room
4. OPERATION AND FUNCTIONS
INPUT CONTROL OBJECT
CONTENTS REMARKS
I DUCT/ F/ R Sensor
Flow Sensor
Freezer Set
Compressor
R-ice Fan
1. Ice Room Sensor on/off Setting Value of Ice maker room
2. Ice storage mode : After 1 hour detect full Ice switch and when Five times of consecutive
water supply failure to Ice Maker.
3. Ice Make mode : Enter it 120 minutes during Ice storage mode later that RT 15 under
4. R-ice Fan are Close of Deforst Mode
5. Comp and R-ice Fan turn On about 10 hours of Quick Ice Mode
Ice storage
mode
Ice make mode Precool
RT<59
(15)
59(15) <
RT
< 73(23)
73(23)
< RT
RT<59
(15)
59
(15) < RT
ON 16(-9)5(-15)0(-18)1(-17)12(-11)16(-9)
OFF 12(-11)-2(-19)-8(-22)-6(-21)5(-15)9(-13)