Daewoo DWC-052CAL Manual do Utilizador Página 41

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 49
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 40
40
40
3) H5 Error - Water temperature error in wool/ delicate course
In case water temperature in wool/ delicate course is 45 or higher
Error buzzer alarm is sounded for 10 seconds per every 10 minutes.
Error display is cleared when turning off/ on power.
4) H6 Error - Abnormality in washing heater
Within 15 minutes after heater operation begins;
In case standard temperature is of 42 or lower: If temperature does not increase by 2 or more In
case standard temperature is higher than 42: If temperature does not increase by1 or more
If temperature falls below standard temperature by 2 or more due to re-supply of water, etc.,
standard temperature is reset as the current temperature and error check time of15 minutes is reset.
Error buzzer alarm is sounded for 10 seconds per every 10 minutes.
Error display is cleared when turning off/ on power.
5) H8 Error - Washing heater overheating
In case washing heater temperature increases by 5 or more within 30 seconds when there is no
water in tank, etc.
Error buzzer alarm is sounded for 10 seconds per every 10 minutes.
Error display is cleared when turning off/ on power.
Vista de página 40
1 2 ... 36 37 38 39 40 41 42 43 44 45 46 47 48 49

Comentários a estes Manuais

Sem comentários